Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 2.237
1.
J Am Heart Assoc ; 13(9): e034004, 2024 May 07.
Article En | MEDLINE | ID: mdl-38639381

BACKGROUND: An epicardial connection (EC) through the intercaval bundle (EC-ICB) between the right pulmonary vein (RPV) and right atrium (RA) is one of the reasons for the need for carina ablation for PV isolation and may reduce the acute and chronic success of PV isolation. We evaluated the intra-atrial activation sequence during RPV pacing after failure of ipsilateral RPV isolation and sought to identify specific conduction patterns in the presence of EC-ICB. METHODS AND RESULTS: This study included 223 consecutive patients who underwent initial catheter ablation of atrial fibrillation. If the RPV was not isolated using circumferential ablation or reconnected during the waiting period, an exit map was created during mid-RPV carina pacing. If the earliest site on the exit map was the RA, the patient was classified into the EC-ICB group. The exit map, intra-atrial activation sequence, and RPV-high RA time were evaluated. First-pass isolation of the RPV was not achieved in 36 patients (16.1%), and 22 patients (9.9%) showed reconnection. Twelve and 28 patients were classified into the EC-ICB and non-EC-ICB groups, respectively, after excluding those with multiple ablation lesion sets or incomplete mapping. The intra-atrial activation sequence showed different patterns between the 2 groups. The RPV-high RA time was significantly shorter in the EC-ICB than in the non-EC-ICB group (69.2±15.2 versus 148.6±51.2 ms; P<0.001), and RPV-high RA time<89.0 ms was highly predictive of the existence of an EC-ICB (sensitivity, 91.7%; specificity, 89.3%). CONCLUSIONS: An EC-ICB can be effectively detected by intra-atrial sequencing during RPV pacing, and an RPV-high RA time of <89.0 ms was highly predictive.


Atrial Fibrillation , Cardiac Pacing, Artificial , Catheter Ablation , Heart Atria , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Female , Male , Catheter Ablation/methods , Middle Aged , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Cardiac Pacing, Artificial/methods , Aged , Heart Atria/physiopathology , Heart Atria/surgery , Treatment Outcome , Retrospective Studies , Pericardium/surgery , Pericardium/physiopathology , Heart Conduction System/physiopathology , Action Potentials , Electrophysiologic Techniques, Cardiac , Heart Rate/physiology
2.
Europace ; 26(5)2024 May 02.
Article En | MEDLINE | ID: mdl-38607938

AIMS: Atrial fibrillation (AF) recurs in about one-third of patients after catheter ablation (CA), mostly in the first year. Little is known about the electrophysiological findings and the effect of re-ablation in very late AF recurrences (VLR) after more than 1 year. The aim of this study was to determine the characteristics and outcomes of the first repeat CA after VLR of AF after index CA. METHODS AND RESULTS: We analysed patients from a prospective Swiss registry that underwent a first repeat ablation procedure. Patients were stratified depending on the time to recurrence after index procedure: early recurrence (ER) for recurrences within the first year and late recurrence (LR) if the recurrence was later. The primary endpoint was freedom from AF in the first year after repeat ablation. Out of 1864 patients included in the registry, 426 patients undergoing a repeat ablation were included in the analysis (28% female, age 63 ± 9.8 years, 46% persistent AF). Two hundred and ninety-one patients (68%) were stratified in the ER group and 135 patients (32%) in the LR group. Pulmonary vein reconnections were a common finding in both groups, with 93% in the ER group compared to 86% in the LR group (P = 0.052). In the LR group, 40 of 135 patients (30%) had a recurrence of AF compared to 90 of 291 patients (31%) in the ER group (log-rank P = 0.72). CONCLUSION: There was no association between the time to recurrence of AF after initial CA and the characteristics and outcomes of the repeat procedure.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Recurrence , Registries , Reoperation , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Catheter Ablation/adverse effects , Catheter Ablation/methods , Female , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Male , Middle Aged , Aged , Time Factors , Switzerland/epidemiology , Risk Factors , Treatment Outcome , Prospective Studies
3.
J Cardiovasc Electrophysiol ; 35(5): 886-894, 2024 May.
Article En | MEDLINE | ID: mdl-38433316

INTRODUCTION: Through systematic scientific rigor, the CLOSE guided workflow was developed and has been shown to improve pulmonary vein isolation durability. However, this technique was developed at a time when using power-controlled ablation catheters with conventional power ranges was the norm. There has been increased adoption of a high-power and very high-power short-duration ablation practice propelled by the availability of the temperature-controlled radiofrequency QDOT MICRO catheter. METHODS: There are fundamental differences in biophysics between very high-powered temperature guided ablation and conventional ablation strategy that may impact patient outcomes. The catheter's design and ablation modes offer flexibility in technique while accommodating the individual operator's clinical discretion and preference to deliver a durable, transmural, and contiguous lesion set. RESULTS: Here, we provide recommendations for 3 different workflows using the QDOT MICRO catheter in a step-by-step manner for pulmonary vein isolation based on our cumulative experience as early adopters of the technology and the data available in the scientific literature. CONCLUSIONS: With standardization, temperature-controlled ablation with the QDOT MICRO catheter provides operators the flexibility of implementing different ablation strategies to ensure durable contiguous pulmonary vein isolation depending on patient characteristics.


Atrial Fibrillation , Cardiac Catheters , Catheter Ablation , Equipment Design , Pulmonary Veins , Humans , Action Potentials , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Catheter Ablation/instrumentation , Heart Rate , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Temperature , Time Factors , Treatment Outcome , Workflow
5.
J Am Soc Echocardiogr ; 37(5): 530-537, 2024 May.
Article En | MEDLINE | ID: mdl-38341053

BACKGROUND: Data on the prognostic factors after mitral valve (MV) transcatheter edge-to-edge repair (TEER; MV-TEER) are limited. Pulsed-wave Doppler interrogation of pulmonary vein flow (PVF) is a convenient method to assess the hemodynamic burden of residual mitral regurgitation (MR), which could be of utility as a predictor of outcomes. METHODS: Patients that underwent MV-TEER between May 2014 and December 2021 at our institution were evaluated. Pulmonary vein flow patterns post-MV-TEER were reviewed on the procedural transesophageal echocardiogram and classified as normal (systolic dominant or codominant) or abnormal (systolic blunting or reversal). The PVF pattern was correlated with all-cause mortality at follow-up. RESULTS: Two-hundred sixty-five patients had diagnostic PVF post-MV-TEER, with 73 (27.5%) categorized as normal and 192 (72.5%) categorized as abnormal. Patients with abnormal PVF morphology were more likely to have atrial fibrillation (70% vs 42%, P < .001) and greater than moderate residual MR (16% vs 3%, P = .01) and had higher mean left atrial pressure (18.1 ± 5.0 vs 15.9 ± 4.2 mm Hg, P = .002) and left atrial V wave (26.6 ± 8.5 vs 21.4 ± 7.3 mm Hg, P < .001) postprocedure. In multivariable analysis, abnormal PVF morphology post-MV-TEER was independently associated with mortality at follow-up (hazard ratio = 1.70; 95% CI, 1.06-2.74; P = .03) after correction for end-stage renal disease, atrial fibrillation, and residual MR. Results were similar in subgroups of patients with moderate or less and those with mild or less residual MR. CONCLUSIONS: Pulmonary vein flow morphology is a simple and objective tool to assess MR severity immediately post-MV-TEER and offers important prognostic information to optimize procedural results. Additional studies are needed to determine whether patients with abnormal PVF pattern post-MV-TEER would benefit from more intensive goal-directed medical therapy postprocedure.


Cardiac Catheterization , Echocardiography, Transesophageal , Mitral Valve Insufficiency , Mitral Valve , Pulmonary Veins , Humans , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Male , Female , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Aged , Echocardiography, Transesophageal/methods , Cardiac Catheterization/methods , Retrospective Studies , Survival Rate , Prognosis , Echocardiography, Doppler, Pulsed/methods
6.
Rev. urug. cardiol ; 38(1): e405, 2023. ilus, tab
Article Es | LILACS, UY-BNMED, BNUY | ID: biblio-1515549

La ablación de las venas pulmonares se ha convertido en un tratamiento clave para fibrilación auricular (FA). Sin embargo, pueden ocurrir recurrencias. La estrategia disponible para la ablación después de una recurrencia de FA es controvertida, compleja y desafiante, y la información es limitada. Mediante la presentación de una serie de casos se resumen y discuten elementos clave en la comprensión y tratamiento del paciente con FA recurrente sintomática después de un procedimiento inicial de ablación de venas pulmonares que requiere un nuevo procedimiento de ablación. En las últimas décadas se ha obtenido una mejor comprensión de los mecanismos fisiopatológicos implicados en la FA recurrente posterior a ablación de venas pulmonares, lo que permite identificar factores asociados, crear scores predictores e implementar técnicas de optimización o estrategias adicionales para mejorar la durabilidad y la eficacia del aislamiento de venas pulmonares. Debido a que la reconexión de venas pulmonares es un hallazgo típico durante los procedimientos repetidos, ésta debe ser considerada el objetivo principal de una nueva ablación. Las estrategias de ablación adicional (desencadenantes extrapulmonares o sustratos arritmogénicos) son controvertidas y requieren investigaciones futuras.


Pulmonary vein ablation has become a key treatment for atrial fibrillation (AF). However, recurrences can occur. The ideal strategy for ablation after AF recurrence is controversial, complex, and challenging, with limited data available. By presenting a series of cases, we summarize and discuss key elements in the understanding and treatment of patients with symptomatic recurrent AF after an initial pulmonary vein ablation procedure who are subjected to a new ablation procedure. In recent decades, there has been a better understanding of the pathophysiological mechanisms involved in recurrent AF after pulmonary vein ablation, making it possible to identify associated factors, create predictive scores and implement optimization techniques or additional strategies to improve the durability and efficacy of pulmonary veins isolation. Because pulmonary vein reconnection is a typical finding during repeat procedures, it should be considered the primary goal for a repeat ablation procedure. Additional ablation strategies (extrapulmonary triggers or arrhythmogenic substrates) are controversial and require further investigation.


A ablação das veias pulmonares tornou-se um tratamento chave para fibrilação atrial (FA). No entanto, podem ocorrer recorrências. A estratégia ideal para a ablação após uma recorrência da FA é controversa, complexa e desafiadora e existem dados limitados. Através da apresentação de uma série de casos resumimos e discutimos elementos chave no entendimento e tratamento do paciente com FA recorrente sintomática após um procedimento inicial de ablação de veias pulmonares, que são submetidos a um novo procedimento de ablação. Nas últimas décadas obteve-se uma melhor compressão dos mecanismos fisiopatológicos envolvidos na FA recorrente pós-ablação de veias pulmonares, isso permite identificar fatores associados, criar scores preditores, implementar técnicas de otimização ou estratégias adicionais para melhorar a durabilidade e eficácia do isolamento de veias pulmonares. Dado que a reconexão de veias pulmonares é um achado típico durante os procedimentos repetidos deve ser considerado o objetivo principal para uma nova ablação. As estratégias de ablação adicional (desencadeadores extrapulmonares ou substratos arritmogénicos) são controversas e requerem investigação futura.


Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Catheter Ablation , Pulmonary Veins/physiopathology , Recurrence , Atrial Fibrillation/physiopathology
8.
Respir Res ; 23(1): 29, 2022 Feb 14.
Article En | MEDLINE | ID: mdl-35164757

BACKGROUND: Chest computed tomography (CT) is a widely used method to assess morphological and dynamic abnormalities in chronic obstructive pulmonary disease (COPD). The small pulmonary vascular cross-section (CSA), quantitatively extracted from volumetric CT, is a reliable indicator for predicting pulmonary vascular changes. CSA is associated with the severity of symptoms, pulmonary function tests (PFT) and emphysema and in COPD patients the severity increases over time. We analyzed the correlation longitudinal changes in pulmonary vascular parameters with clinical parameters in COPD patients. MATERIALS AND METHODS: A total of 288 subjects with COPD were investigated during follow up period up to 6 years. CT images were classified into five subtypes from normal to severe emphysema according to percentage of low-attenuation areas less than -950 and -856 Hounsfield units (HU) on inspiratory and expiratory CT (LAA-950, LAA-856exp). Total number of vessels (Ntotal) and total number of vessels with area less than 5 mm2 (N<5 mm) per 1 cm2 of lung surface area (LSA) were measured at 6 mm from the pleural surface. RESULTS: Ntotal/LSA and N<5 mm/LSA changed from 1.16 ± 0.27 to 0.87 ± 0.2 and from 1.02 ± 0.22 to 0.78 ± 0.22, respectively, during Global Initiative for Chronic Obstructive Lung Disease (GOLD) stage progression. Both parameters changed from normal to severe emphysema according to CT subtype from 1.39 ± 0.21 to 0.74 ± 0.17 and from 1.18 ± 0.19 to 0.67 ± 0.15, respectively. LAA-950 and LAA-856exp were negatively correlated with Ntotal/LSA (r = - 0.738, - 0.529) and N<5 mm /LSA (r = - 0.729, -- .497). On the other hand, pulmonary function test (PFT) results showed a weak correlation with Ntotal/LSA and N<5 mm/LSA (r = 0.205, 0.210). The depth in CT subtypes for longitudinal change both Ntotal/LSA and N<5 mm/LSA was (- 0.032, - 0.023) and (- 0.027) in normal and SAD, respectively. CONCLUSIONS: Quantitative computed tomography features faithfully reflected pulmonary vessel alterations, showing in particular that pulmonary vascular alteration started.


Lung/diagnostic imaging , Multidetector Computed Tomography/methods , Pulmonary Artery/diagnostic imaging , Pulmonary Disease, Chronic Obstructive/diagnosis , Pulmonary Veins/diagnostic imaging , Vascular Resistance/physiology , Adult , Aged , Aged, 80 and over , Disease Progression , Female , Follow-Up Studies , Forced Expiratory Volume/physiology , Humans , Lung/physiopathology , Male , Middle Aged , Prospective Studies , Pulmonary Artery/physiopathology , Pulmonary Disease, Chronic Obstructive/physiopathology , Pulmonary Veins/physiopathology , Respiratory Function Tests , Time Factors
9.
BMC Cardiovasc Disord ; 22(1): 38, 2022 02 11.
Article En | MEDLINE | ID: mdl-35148671

BACKGROUND: Left atrial appendage closure (LAAC) combined with radiofrequency catheter ablation (RFCA) as a hybrid procedure is commonly performed to treat atrial fibrillation (AF). Although this treatment carries a low risk of coronary artery spasm (CAS), and has never been observed in LAAC procedure, caution still needed to be taken. We presented a case of CAS that occurred in an AF patient during the hybrid procedure. CASE PRESENTATION: The patient was a 65-year-old man with paroxysmal AF who developed CAS during RFCA and LAAC. In this case, LAAC was performed ahead of RFCA. After atrial septal puncture, the occluder was advanced into left atrium through delivery sheath, and successfully deployed in the LAA. After verifying the assessment of "PASS" criteria, we decided to release the device. However, before releasing the occluder in LAAC, the patient's blood pressure (BP) fell to 70/45 mmHg with heart rate (HR) drop and ST-segment elevation in II, III, and aVF and reciprocal ST-segment depression in I and aVL. Isotonic sodium chloride load was administered. After 3 min, the BP and HR raised, and ST-segment returned to normal. The occluder was successfully released after the stable condition of the patient. Then, RFCA was sequentially performed. When isolating the right pulmonary veins, the patient's BP and HR fell again with ST-segment elevation in inferior leads. Spontaneous ventricular tachycardia and fibrillation developed rapidly and defibrillation was performed immediately with success. Coronary angiography revealed the obstruction of the right coronary artery which disappeared completely after intracoronary nitroglycerin injection (1 mg). Under systemic diltiazem infusion, the RFCA procedure was accomplished. After the procedure, the patient recovered without any neurologic deficit, and CAS has never recurred with isosorbide mononitrate treatment during follow-up. CONCLUSIONS: CAS is a rare complication associated with AF hybrid procedure. Attention should be paid to this rare but potentially life-threatening complication.


Atrial Appendage/surgery , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Coronary Vasospasm/etiology , Coronary Vessels/physiopathology , Pulmonary Veins/surgery , Vasoconstriction , Aged , Atrial Appendage/physiopathology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Coronary Angiography , Coronary Vasospasm/diagnostic imaging , Coronary Vasospasm/drug therapy , Coronary Vasospasm/physiopathology , Coronary Vessels/diagnostic imaging , Coronary Vessels/drug effects , Electrocardiography , Humans , Male , Pulmonary Veins/physiopathology , Treatment Outcome , Vasoconstriction/drug effects , Vasodilator Agents/therapeutic use
13.
J Thorac Cardiovasc Surg ; 163(2): 387-395.e3, 2022 Feb.
Article En | MEDLINE | ID: mdl-33966882

BACKGROUND: Previous studies have demonstrated increased early mortality and pulmonary vein reintervention for patients with total anomalous pulmonary venous connection (TAPVC) and heterotaxy syndrome (HTX+) compared with patients with TAPVC without heterotaxy syndrome (HTX-). We aimed to evaluate the longitudinal risk of pulmonary vein reintervention and mortality in HTX + patients. METHODS: A retrospective review was performed to identify longitudinal interventions in patients with TAPVC seen at a single center from 1995 to 2019. The mean cumulative interventions were described for all patients using the Nelson-Aalen estimator. Survival with TAPVC was described using Kaplan-Meier estimates. RESULTS: A total of 336 patients were identified with TAPVC, of whom 118 (35%) had heterotaxy syndrome. Functional single ventricles were identified in 106 of these 118 HTX + patients (90%) and in 14 of 218 HTX- patients (6%) (P < .001). Obstructed TAPVC (OBS+) was present in 49 of 118 HTX + patients (42%) and in 87 of 218 HTX- patients (40%) (P = .89). The median duration of follow-up was 6.5 years. Five-year survival was 69% for HTX+/OBS + patients, 72% for HTX+/OBS- patients, 86% for HTX-/OBS + patients, and 95% for HTX-/OBS- patients (P < .0001, log-rank test). The mean number of pulmonary vein interventions at the median follow-up time was greater in the HTX+/OBS + patients compared with HTX+/OBS- patients (mean, 2.0 vs 1.1; P = .030), HTX-/OBS + patients (mean, 1.3; P = .033), and HTX-/OBS- patients (mean, 1.3; P = .029). CONCLUSIONS: Among the 4 cohorts, HTX+ was associated with a higher rate of mortality, and HTX+/OBS+ was associated with a greater number of pulmonary vein interventions. This may be due in part to the high prevalence of single ventricle physiology in the HTX + cohort.


Heterotaxy Syndrome , Pulmonary Veins/surgery , Pulmonary Veno-Occlusive Disease/surgery , Scimitar Syndrome/surgery , Vascular Surgical Procedures , Female , Heterotaxy Syndrome/diagnostic imaging , Heterotaxy Syndrome/mortality , Heterotaxy Syndrome/physiopathology , Humans , Male , Postoperative Complications/mortality , Postoperative Complications/surgery , Pulmonary Veins/abnormalities , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/physiopathology , Pulmonary Veno-Occlusive Disease/diagnostic imaging , Pulmonary Veno-Occlusive Disease/mortality , Pulmonary Veno-Occlusive Disease/physiopathology , Recurrence , Reoperation , Retrospective Studies , Scimitar Syndrome/diagnostic imaging , Scimitar Syndrome/mortality , Scimitar Syndrome/physiopathology , Time Factors , Treatment Outcome , Vascular Surgical Procedures/adverse effects , Vascular Surgical Procedures/mortality
16.
Circ Arrhythm Electrophysiol ; 15(1): e010168, 2022 01.
Article En | MEDLINE | ID: mdl-34964367

BACKGROUND: Pulsed field ablation (PFA) is a novel form of ablation using electrical fields to ablate cardiac tissue. There are only limited data assessing the feasibility and safety of this type of ablation in humans. METHODS: PULSED AF (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF; https://www.clinicaltrials.gov; unique identifier: NCT04198701) is a nonrandomized, prospective, multicenter, global, premarket clinical study. The first-in-human pilot phase evaluated the feasibility and efficacy of pulmonary vein isolation using a novel PFA system delivering bipolar, biphasic electrical fields through a circular multielectrode array catheter (PulseSelect; Medtronic, Inc). Thirty-eight patients with paroxysmal or persistent atrial fibrillation were treated in 6 centers in Australia, Canada, the United States, and the Netherlands. The primary outcomes were ability to achieve acute pulmonary vein isolation intraprocedurally and safety at 30 days. RESULTS: Acute electrical isolation was achieved in 100% of pulmonary veins (n=152) in the 38 patients. Skin-to-skin procedure time was 160±91 minutes, left atrial dwell time was 82±35 minutes, and fluoroscopy time was 28±9 minutes. No serious adverse events related to the PFA system occurred in the 30-day follow-up including phrenic nerve injury, esophageal injury, stroke, or death. CONCLUSIONS: In this first-in-human clinical study, 100% pulmonary vein isolation was achieved using only PFA with no PFA system-related serious adverse events. Graphic Abstract: A graphic abstract is available for this article.


Atrial Fibrillation/surgery , Catheter Ablation , Pulmonary Veins/surgery , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Australia , Canada , Catheter Ablation/adverse effects , Feasibility Studies , Female , Humans , Male , Middle Aged , Netherlands , Operative Time , Pilot Projects , Prospective Studies , Pulmonary Veins/physiopathology , Time Factors , Treatment Outcome , United States
18.
BMC Cardiovasc Disord ; 21(1): 483, 2021 10 07.
Article En | MEDLINE | ID: mdl-34620082

BACKGROUND: Early recurrences of atrial arrhythmias (ERAA) after atrial fibrillation (AF) catheter ablation do not predict procedural failure. A well-demarcated homogeneous lesion delivered by cryoballoon is less arrhythmogenic, and the recommended three-months blanking period may not refer to cryoballoon ablation (CBA). OBJECTIVE: We aimed to evaluate the predictive role of ERAA after second-generation CBA using an implantable loop recorder. METHODS: This prospective observational study enrolled 100 patients (58 males, median age 58) with paroxysmal/persistent AF undergoing pulmonary vein (PV) CBA using second-generation cryoballoon with simultaneous ECG loop recorder implantation. The duration of follow-up was 12 months, with scheduled visits at 3, 6 and 12 months. RESULTS: 99 patients from 100 completed the 12-month follow-up period. ERAA occurred in 31.3 % of patients. 83.9 % of patients with ERAA also developed late recurrences. The 12-month freedom from AF in patients with ERAA was significantly lower than in those without ERAA (p < 0.0001). Non-paroxysmal AF and longer arrhythmia history were associated with increased risk of both early (HR 3.27; 95 % CI 1.32-8.08; p = 0.010 and HR 1.0147; 95 % CI 1.008-1.086; p = 0.015, respectively) and late recurrences (HR 3.89; 95 % CI 1.67-9.04; p = 0.002 and HR 1.0142; 95 % CI 1.007-1.078; p = 0.019, respectively) of AF. ERAA were another predictor for procedural failure (HR 15.2; 95 % CI (6.42-35.99; p = 0.019). CONCLUSIONS: ERAA occurred in the third of the patients after PV second-generation CBA and are strongly associated with procedural failure. Longer duration of AF history and persistent AF are independent predictors of AF's early and late recurrence.


Atrial Fibrillation/surgery , Cryosurgery/adverse effects , Electrocardiography, Ambulatory , Pulmonary Veins/surgery , Remote Sensing Technology , Action Potentials , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Electrocardiography, Ambulatory/instrumentation , Female , Heart Rate , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Pulmonary Veins/physiopathology , Recurrence , Remote Sensing Technology/instrumentation , Reproducibility of Results , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
19.
BMC Cardiovasc Disord ; 21(1): 387, 2021 08 09.
Article En | MEDLINE | ID: mdl-34372779

BACKGROUND: Transmural lesion creation is essential for effective atrial fibrillation (AF) ablation. Lesion characteristics between conventional energy and high-power short-duration (HPSD) setting in contact force-guided (CF) ablation for AF remained unclear. METHODS: Eighty consecutive AF patients who received CF with conventional energy setting (power control: 25-30 W, force-time integral = 400 g s, n = 40) or with HPSD (power control: 40-50 W, 10 s, n = 40) ablation were analyzed. Of them, 15 patients in each conventional and HPSD group were matched by age and gender respectively for ablation lesions analysis. Type A and B lesions were defined as a lesion with and without significant voltage reduction after ablation, respectively. The anatomical distribution of these lesions and ablation outcomes among the 2 groups were analyzed. RESULTS: 1615 and 1724 ablation lesions were analyzed in the conventional and HPSD groups, respectively. HPSD group had a higher proportion of type A lesion compared to conventional group (P < 0.01). In the conventional group, most type A lesions were at the right pulmonary vein (RPV) posterior wall (50.2%) whereas in the HPSD group, most type A lesions were at the RPV anterior wall (44.0%) (P = 0.04). The procedure time and ablation time were significantly shorter in the HPSD group than that in the conventional group (91.0 ± 12.1 vs. 124 ± 14.2 min, P = 0.03; 30.7 ± 19.2 vs. 57.8 ± 21 min, P = 0.02, respectively). At a mean follow-up period of 11 ± 1.4 months, there were 13 and 7 patients with recurrence in conventional and HPSD group respectively (P = 0.03). CONCLUSION: Optimal ablation lesion characteristics and distribution after conventional and HPSD ablation differed significantly. HPSD ablation had shorter ablation time and lower recurrence rate than did conventional ablation.


Atrial Fibrillation/surgery , Catheter Ablation/methods , Pulmonary Veins/injuries , Age Factors , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/drug therapy , Case-Control Studies , Catheter Ablation/instrumentation , Catheter Ablation/statistics & numerical data , Electrophysiologic Techniques, Cardiac , Female , Humans , Male , Middle Aged , Operative Time , Pulmonary Veins/physiopathology , Recurrence , Sex Factors , Smart Materials , Time Factors , Treatment Outcome
20.
Prog Cardiovasc Dis ; 66: 86-91, 2021.
Article En | MEDLINE | ID: mdl-34332664

This article reviews and compares the rationale and evidence supporting high-power, short-duration radiofrequency (RF) ablation with those of conventional-power, conventional-duration RF ablation for atrial fibrillation (AF). The pros and cons of each approach, biophysics of ablation, pre-clinical studies informing clinical utilization, and the accumulated clinical evidence are presented. Both conventional-power, conventional-duration RF ablation and high-power, short-duration ablation are similarly safe, and effective approaches for AF ablation. Theoretical advantages of high-power, short-duration ablation, including greater procedure efficiency and limited conductive heating of collateral structures, must be weighed against the narrower safety margin related to rapid energy delivery during high power ablation.


Atrial Fibrillation/surgery , Catheter Ablation , Pulmonary Veins/surgery , Action Potentials , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Catheter Ablation/adverse effects , Catheter Ablation/mortality , Clinical Decision-Making , Heart Rate , Humans , Pulmonary Veins/physiopathology , Recovery of Function , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
...